Send Message

DMF Electromagnetic Pneumatic Pulse Valve Air Dust Proof Valve industrial environment health Application

Product Details:
Place of Origin: CHINA
Brand Name: NBSANMINSE
Certification: ISO9001
Model Number: QD - Z - 40S / 50S
Payment & Shipping Terms:
Minimum Order Quantity: 20
Price: Negotiation
Packaging Details: Plastic Bags , Boxes , Carton , Pallet Or As Customer Advice
Delivery Time: Negotiation
Payment Terms: L/C, T/T, Western Union
Supply Ability: Negotiation

Detail Information

Pressure: 0 . 3 - 0 . 6MPa Temperature: - 25 ~ 60 ℃
Relative Humidity: ≤ 85 % Medium: Clean Air
Voltage: DC24V / AC110V / Etc Diaphragm: Double Diaphragm
Diameter: G1 - 1 / 2 " , G2 " Body: ADC 12 Die Cast
High Light:

pulse air valve

,

pulse jet solenoid valve

Product Description

QD - Z - 40S / 50S Series Electromagnetic Pulse Valve GOYEN Replace  G1 - 1 / 2 " , G2 " Dust proof valve Dust Control Valve
 
 
 
Usage
 
Electromagnetic valve ( Also called diaphragm valve ) is the” switch “for compressed air in the dust clean blowing system of the pulse bag filter . Controlled by the output signals of the pulse jet control device , it makes dust clean to the filter bags cell by cell to keep the resistance of thebaghouse within the set range and thus guarantee the processing functions and the dust collecting efficiency of the baghouse .
 
 
Z type electromagnetic pulse valves is a right angle valve , with the 90 degree , angle between the inlet and outlet , which is suitable for the installation connection between the gas dome and the baghouse blow tube provide good air flow and dust clean pulses satisfying the requirements .
 

Material Construction                                                                                                                                     
 
Body : ADC12 die cast
Armature : 430FR stainless steel
Diaphragm: Nitrile or viton
Spring : 321 Stainless steel
Fasteners : 302 Stainless steel
 
Good Quality membranes shall be selected and used fo all the valves , with each part checked in each manufacturing procedure , and put into the assembly ling conforming to all the procedures . Every finished valve shall be taken the electriferous blowing test .

During installation and commissioning                                                                                                          
 
Failure phenomena
 
1 . The valves cannot all be opened, but the leading part does act.
2 . Some valves do not work, but the others are normal.
3 . The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.
4 . Some valves cannot be closed. There is leakage.
5 . A valve closing is slowly.
 
Possible Reason
 
1 . Check the gas dome pressure to see if it is too low.
2 . Check the valve coil connection and coil
3 ( 1 ) . Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.
3 ( 2 ) . Z-valve. The valve inlet and blowing muzzle are installed backwards.
4 . There is some dirt or debris on the membrane, ii is blocking the moving iron core.
5 . The membrane orifice is blocked.
 
Troubleshooting
 
1 . Check the leakage
2 . Replace the accessories
3 ( 1 ) . Check the leakage
3 ( 2 ) . Re-install
4 . Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
5 . Dredge the membrane orifice
 
 
During use period
 
Failure phenomena
 
1 . Some valves are leaking. The membrane cannot close tightly and the valve is always open a
little.
2 . Coil is hot and burned out.
3 . Voltage exists but the valve does not operate.
4 . Ambient temperature is below -20℃. The valve is leaking and cannot open.
 
Possible Reason
 
1 . There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.
2 . It has been turned on for too long.
3 . Membrane is damaged and the orifice is blocked.
4 . Ambient temperature is too low and here is frost in the valve.
 
Troubleshooting
 
1 . Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
2 . Check the working condition of the control system.
3 . Replace the accessories in time.
4 . Pay attention to insulation and maintaining proper temperatures.


DMF Electromagnetic Pneumatic Pulse Valve Air Dust Proof Valve industrial environment health Application 0DMF Electromagnetic Pneumatic Pulse Valve Air Dust Proof Valve industrial environment health Application 1DMF Electromagnetic Pneumatic Pulse Valve Air Dust Proof Valve industrial environment health Application 2

Get in touch with us

Enter Your Message

You Might Be Into These
sanmin5@pneuhydr.com
+8615168536055
15168536055
fhtrust
0086-15168536055